Enumerator |
---|
BT_MESH_LIGHT_CTRL_PROP_ILLUMINANCE_ON | Target ambient illuminance in the On state.
- Unit: Lux
- Encoding: 24 bit unsigned scalar (Resolution: 0.01 lx)
- Range: 0 to 167772.13
|
BT_MESH_LIGHT_CTRL_PROP_ILLUMINANCE_PROLONG | Target ambient illuminance in the Prolong state.
- Unit: Lux
- Encoding: 24 bit unsigned scalar (Resolution: 0.01 lx)
- Range: 0 to 167772.13
|
BT_MESH_LIGHT_CTRL_PROP_ILLUMINANCE_STANDBY | Target ambient illuminance in the Standby state.
- Unit: Lux
- Encoding: 24 bit unsigned scalar (Resolution: 0.01 lx)
- Range: 0 to 167772.13
|
BT_MESH_LIGHT_CTRL_PROP_LIGHTNESS_ON | Lightness in the On state.
- Unit: Unitless
- Encoding: 16 bit unsigned scalar (Resolution: 1)
- Range: 0 to 65535
|
BT_MESH_LIGHT_CTRL_PROP_LIGHTNESS_PROLONG | Lightness in the Prolong state.
- Unit: Unitless
- Encoding: 16 bit unsigned scalar (Resolution: 1)
- Range: 0 to 65535
|
BT_MESH_LIGHT_CTRL_PROP_LIGHTNESS_STANDBY | Lightness in the Standby state.
- Unit: Unitless
- Encoding: 16 bit unsigned scalar (Resolution: 1)
- Range: 0 to 65535
|
BT_MESH_LIGHT_CTRL_PROP_REG_ACCURACY | Regulator Accuracy.
- Unit: Percent
- Encoding: 8 bit unsigned scalar (Resolution: 0.5 %)
- Range: 0 to 100.0
|
BT_MESH_LIGHT_CTRL_PROP_TIME_FADE_PROLONG | Fade time for fading to the Prolong state.
- Unit: Seconds
- Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
- Range: 0 to 16777.214
|
BT_MESH_LIGHT_CTRL_PROP_TIME_FADE_ON | Fade time for fading to the On state.
- Unit: Seconds
- Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
- Range: 0 to 16777.214
|
BT_MESH_LIGHT_CTRL_PROP_TIME_FADE_STANDBY_AUTO | Fade time for fading to the Standby state (auto mode).
- Unit: Seconds
- Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
- Range: 0 to 16777.214
|
BT_MESH_LIGHT_CTRL_PROP_TIME_FADE_STANDBY_MANUAL | Fade time for fading to the Standby state (manual mode).
- Unit: Seconds
- Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
- Range: 0 to 16777.214
|
BT_MESH_LIGHT_CTRL_PROP_TIME_OCCUPANCY_DELAY | Delay from Occupancy sensor reports until the light turns on.
- Unit: Seconds
- Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
- Range: 0 to 16777.214
|
BT_MESH_LIGHT_CTRL_PROP_TIME_PROLONG | Time to stay in the Prolong state.
- - Unit: Seconds
- Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
- Range: 0 to 16777.214
|
BT_MESH_LIGHT_CTRL_PROP_TIME_ON | Time to stay in the On state.
- Unit: Seconds
- Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
- Range: 0 to 16777.214
|