◆ bt_mesh_light_ctrl_prop

#include <include/bluetooth/mesh/light_ctrl.h>

Light Lightness Control properties

Enumerator
BT_MESH_LIGHT_CTRL_PROP_ILLUMINANCE_ON 

Target ambient illuminance in the On state.

  • Unit: Lux
  • Encoding: 24 bit unsigned scalar (Resolution: 0.01 lx)
  • Range: 0 to 167772.13
BT_MESH_LIGHT_CTRL_PROP_ILLUMINANCE_PROLONG 

Target ambient illuminance in the Prolong state.

  • Unit: Lux
  • Encoding: 24 bit unsigned scalar (Resolution: 0.01 lx)
  • Range: 0 to 167772.13
BT_MESH_LIGHT_CTRL_PROP_ILLUMINANCE_STANDBY 

Target ambient illuminance in the Standby state.

  • Unit: Lux
  • Encoding: 24 bit unsigned scalar (Resolution: 0.01 lx)
  • Range: 0 to 167772.13
BT_MESH_LIGHT_CTRL_PROP_LIGHTNESS_ON 

Lightness in the On state.

  • Unit: Unitless
  • Encoding: 16 bit unsigned scalar (Resolution: 1)
  • Range: 0 to 65535
BT_MESH_LIGHT_CTRL_PROP_LIGHTNESS_PROLONG 

Lightness in the Prolong state.

  • Unit: Unitless
  • Encoding: 16 bit unsigned scalar (Resolution: 1)
  • Range: 0 to 65535
BT_MESH_LIGHT_CTRL_PROP_LIGHTNESS_STANDBY 

Lightness in the Standby state.

  • Unit: Unitless
  • Encoding: 16 bit unsigned scalar (Resolution: 1)
  • Range: 0 to 65535
BT_MESH_LIGHT_CTRL_PROP_REG_ACCURACY 

Regulator Accuracy.

  • Unit: Percent
  • Encoding: 8 bit unsigned scalar (Resolution: 0.5 %)
  • Range: 0 to 100.0
BT_MESH_LIGHT_CTRL_PROP_TIME_FADE_PROLONG 

Fade time for fading to the Prolong state.

  • Unit: Seconds
  • Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
  • Range: 0 to 16777.214
BT_MESH_LIGHT_CTRL_PROP_TIME_FADE_ON 

Fade time for fading to the On state.

  • Unit: Seconds
  • Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
  • Range: 0 to 16777.214
BT_MESH_LIGHT_CTRL_PROP_TIME_FADE_STANDBY_AUTO 

Fade time for fading to the Standby state (auto mode).

  • Unit: Seconds
  • Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
  • Range: 0 to 16777.214
BT_MESH_LIGHT_CTRL_PROP_TIME_FADE_STANDBY_MANUAL 

Fade time for fading to the Standby state (manual mode).

  • Unit: Seconds
  • Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
  • Range: 0 to 16777.214
BT_MESH_LIGHT_CTRL_PROP_TIME_OCCUPANCY_DELAY 

Delay from Occupancy sensor reports until the light turns on.

  • Unit: Seconds
  • Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
  • Range: 0 to 16777.214
BT_MESH_LIGHT_CTRL_PROP_TIME_PROLONG 

Time to stay in the Prolong state.

  • - Unit: Seconds
  • Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
  • Range: 0 to 16777.214
BT_MESH_LIGHT_CTRL_PROP_TIME_ON 

Time to stay in the On state.

  • Unit: Seconds
  • Encoding: 24 bit unsigned scalar (Resolution: 1 ms)
  • Range: 0 to 16777.214