◆ sdc_hci_cmd_le_set_periodic_adv_sync_transfer_params()

uint8_t sdc_hci_cmd_le_set_periodic_adv_sync_transfer_params ( const sdc_hci_cmd_le_set_periodic_adv_sync_transfer_params_t * p_params,
sdc_hci_cmd_le_set_periodic_adv_sync_transfer_params_return_t * p_return )

#include <softdevice_controller/include/sdc_hci_cmd_le.h>

LE Set Periodic Advertising Sync Transfer Parameters.

The description below is extracted from Core_v6.0, Vol 4, Part E, Section 7.8.91

The HCI_LE_Set_Periodic_Advertising_Sync_Transfer_Parameters command is used to specify how the Controller will process periodic advertising synchronization information received from the device identified by the Connection_Handle parameter (the "transfer mode").

The Mode parameter specifies the action to be taken when periodic advertising synchronization information is received. If Mode is 0x00, the Controller will ignore the information. Otherwise it will notify the Host and synchronize to the periodic advertising. Mode also specifies whether periodic advertising reports are initially enabled or disabled and whether duplicates are filtered.

The Skip parameter specifies the number of consecutive periodic advertising packets that the receiver may skip after successfully receiving a periodic advertising packet.

The Sync_Timeout parameter specifies the maximum permitted time between successful receives. If this time is exceeded, synchronization is lost.

Irrespective of the value of the Skip parameter, the Controller should stop skipping packets before the Sync_Timeout would be exceeded.

The CTE_Type parameter specifies whether to only synchronize to periodic advertising with certain types of Constant Tone Extension. If the periodic advertiser changes the type of the Constant Tone Extension after the Controller has synchronized with the periodic advertising, it shall remain synchronized.

Note: A value of 0 (i.e. all bits clear) indicates that the presence or absence of a Constant Tone Extension is irrelevant.

This command does not affect any processing of any periodic advertising synchronization information already received from the peer device, whether or not the Controller has yet synchronized to the periodic advertising train it describes.

The parameter values provided by this command override those provided via the HCI_LE_Set_Default_Periodic_Advertising_Sync_Transfer_Parameters command (Section 7.8.92) or any preferences previously set using the HCI_LE_Set_Periodic_Advertising_Sync_Transfer_Parameters command on the same connection.

If the Connection_Handle parameter does not identify a current connection, the Controller shall return the error code Unknown Connection Identifier (0x02).

If the Host sets Mode to 0x03 and the Controller does not support the Periodic Advertising ADI Support feature, then the Controller shall return an error which should use the error code Unsupported Feature or Parameter Value (0x11).

If the Host sets all the non-reserved bits of CTE_Type to 1, then the Controller should return an error using the error code Command Disallowed (0x0C).

Event(s) generated (unless masked away): When the HCI_LE_Set_Periodic_Advertising_Sync_Transfer_Parameters command has completed, an HCI_Command_Complete event shall be generated.

Parameters
[in]p_paramsInput parameters.
[out]p_returnExtra return parameters.
Return values
0if success.
Returns